EDA9033G three-phase electric parameter synthesis module

EDA9033G module is an intelligent three-phase electric parameter data comprehensive acquisition module.The three-meter method is used to accurately measure the three phase current, three phase voltage (true RMS), active power, reactive power, power factor, frequency, positive and negative active power, positive and negative reactive power in three-phase three-wire or three-phase four-wire AC circuits。And with 2 switching input and 2 switching output (1 can be set as the upper and lower limit alarm output of each parameter)。

Category:

Power monitoring module

Key words:

Product description

Main feature

●  EDA9033G module is an intelligent three-phase electric parameter data comprehensive acquisition module.The three-meter method is used to accurately measure the three phase current, three phase voltage (true RMS), active power, reactive power, power factor, frequency, positive and negative active power, positive and negative reactive power in three-phase three-wire or three-phase four-wire AC circuits。And with 2 switching input and 2 switching output (1 can be set as the upper and lower limit alarm output of each parameter)。

●  The input is three-phase voltage (0-500V), three-phase current (0-1000A);The output is a digital signal with an RS-485 or RS-232 interface,There are three communication protocols supported: (ASCII) Advantech ADAM compatible communication protocol, hexadecimal LC-04 protocol, MODBUS-RTU protocol。

Product function

●  The EDA9033G module can be widely used in various industrial control and measurement systems and various distributed/distributed power monitoring systems。
●  The EDA9033G module is a cost-effective intelligent electrical parameter transmitter,It can replace the past current, voltage, power, power factor, electricity and other transmitters and measure the standard output signal of these transmitters in the module,It can greatly reduce the system cost, Convenient field wiring,Improve system reliability。 Its 485 bus output and ASCII code instruction set compatible with NuDAM, ADAM and other modules, so that it can be hung on the same 485 bus with other manufacturers' control modules, and easy computer programming, so that you can easily build your own measurement and control system。
●  Using electromagnetic isolation and photoelectric isolation technology, voltage input, current input and output are completely isolated。

 

Product parameter

●  Input signal
Three-phase AC 50/60Hz voltage and current。Input frequency: 45 ~ 75Hz。
Switching input: 2 channels, passive null contact input, or logic level 0:0 ~ +0.5V or short-circuit, logic level 1: +3V ~ +30V or open circuit。
Voltage range (phase voltage) : 10V, 20V, 50V, 60V, 100V, 200V, 250V, 300V, 400V, 500V optional。
Current range: 1A, 2A, 3A, 5A, 10A, 20A, (50A, 100A, 200A, 500A, 1000A), etc。
Signal processing: 16-bit A/D conversion, 6 channels, each channel is synchronized AC sampling at the rate of 4KHz, module real-time data is 1 second true RMS value (refresh once every 1 second)。
Overload capacity: 1.4倍量程输入可正确测量;瞬间(<10周波)电流5倍,电压3倍量程不损坏。
●  Communication output
Output data: three-phase voltage Ua, Ub, Uc;Three-phase current Ia, Ib, Ic;Active power P, reactive power Q, power factor PF, frequency f, active power Pa, Pb, Pc of each phase;Each phase reactive power Qa, Qb, Qc;Forward active power, reverse active power, forward reactive power, reverse reactive power and other electrical parameters。
Output interface: RS-485 two-wire system ±15KV ESD protection or RS-232 three-wire system ±2KV ESD protection。
Communication rate (Bps) : 1200, 2400, 4800, 9600, 19.2K
Communication protocol: Multi-protocol, a module has ASCII format protocol, hexadecimal LC-04 protocol, MODBUS-RTU protocol。
●  Switching output
2路:三极管集电极开路输出;输入开路电压< 30V,吸入电流<200mA,功耗<500mW。Actuable relay。The 0 channel DO0 can be set as the upper and lower limit alarm output of each parameter;Parameter type can be set, alarm upper and lower limits can be set。
●  Measurement accuracy
Current, voltage, frequency: 0.2级 ; 其它电量:0.Lv.5;Frequency: Maximum error 0.05Hz。
●  Parameter setting
Module address, communication rate, active and reactive power base can be set through the communication interface。
●  Module Power supply +5V±5%, +8 ~ 30V, AC220 (100) V Power consumption: < 0.5W+5V power supply, the consumption current is less than 70mA, the input ripple should be less than 100mV, and the input voltage is 5V±5%。
+8 ~ 30V power supply, the current consumption is less than 70mA, the maximum input voltage must not exceed +32V。AC power supply (50HZ), input voltage is 100V (220V) AC±15% 。
●  Isolation voltage
Input-output: 1000VDC。Current input, voltage input, AC power input, and communication interface output are isolated from each other。
●  Module specification
Dimensions: 122mm *69mm * 73mm Installation: DIN rail card
●  Working environment
Operating temperature: -20℃ ~ 70℃ Storage temperature: -40℃ ~ 85℃ Relative humidity: -5% ~ 95% no condensation

 